![Paul CLIMOS F 200 Original Operating Instructions Download Page 17](http://html1.mh-extra.com/html/paul/climos-f-200/climos-f-200_original-operating-instructions_4022625017.webp)
17
Main menu Information
2.3.1
The main menu
Information
is divided into eight submenus. In the submenus, information on the current
device status as well as selected factory pre-sets (e.g. type of device) are visualised. Using the navigation
buttons, the respective menu is selected and called up with the Enter key.
2.3.1.1 Submenu Current messages
Here, a piece of information (e. g. replace filter) or an error (e.g. broken sensor) is displayed as current
message. In addition to this display, a yellow warning triangle flashes in the upper right edge of the
screen. Only error messages generally lead to switching off the fans.
2.3.1.2 Submenu Last messages
Here, the last three errors that occurred are registered in compliance with the event with date and time. In
addition to this indication, a yellow warning triangle is flashing at the right upper margin of the screen.
2.3.1.3 Submenu Fan speeds
Here, the percentage adjustments of the three fan speeds 1, 2 and 3 (FS1, FS2 and FS3) as well as the
pressed times for un-occupied and boost ventilation are indicated.
2.3.1.4 Submenu Current status of the device
Here, the current device-related supply air temperature and intake air temperature as well as the by-pass
status (closed / open) for devices with by-pass flap or the summer ventilation status (inactive / active) for
devices without by-pass flap are displayed
2.3.1.5 Submenu software versions
In this menu, the devices which are actually connected to the bus and which were identified are displayed
by means of checkmark symbols.
2.3.1.6 Submenu Connected devices
In this menu, the devices which are actually connected to the device-internal BUS and which were
identified are displayed by means of checkmark symbols.
2.3.1.7 Submenu Filter age
Here, the pressed filter run-time and the current remaining run-time of the filter are indicated
.
The filter
run-time is decremented daily.
2.3.1.8 Submenu Operating hours
The following information is displayed:
•
Overall operating hours (time during which the device is connected to the power supply)
•
Operating hours of the fans (time during which the fans are operating)
Main menu Settings
2.3.2
In the main menu
Settings
,
changes by the user are possible which primarily serve the individual
adjustment to the own comfort. Using the navigation buttons, the respective submenu is selected and
called up with the Enter key, whereby only submenus with text highlighted in red can be parameterised.
The settings in the submenu are only applied after having touched Enter!
2.3.2.1 Submenu Fan speeds
Using the navigation buttons, the following can be selected and set here:
•
Fan speed 1 and fan speed 3 (in 1 %-steps)
•
Duration of the boost ventilation (in 5 min-steps)
•
Ventilation intensity for non-occupation (FS1 in min/h-steps)
Summary of Contents for CLIMOS F 200
Page 1: ...Version 2 0_06 2016 EN...
Page 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Page 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Page 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Page 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Page 65: ...65 Product fiche 4 5...