10.
OPERATION WITH AN ELECTRIC GENERATOR
Electrode diameter (mm)
Fixed current value at MMA
and TIG
Minimum generator
power
Ф 2
not more than 80 А
2.9 kVA
Ф 3
not more than 120 А
4.5 kVA
Ф 4
not more than 160 А
6.2 kVA
Ф 5
not more than 200 А
8.0 kVA
ATTENTION!
For trouble-free operation, the output voltage of the
generator must not exceed the permissible limits of 190 - 260 V.
11.
MAINTENANCE
ATTENTION
!!
Before opening the housing of the device, switch it off,
remove the power cord from the mains socket and allow the internal
electronics of the device to discharge (about 5 minutes), and only then
perform the other steps. In case of leaving the device, it is recommended to
set up a sign informing about not turning the device on.
To keep the device in good condition for many years, follow the recommendations:
1.
Carry out a safety check at certain intervals (see chapter "Safety regulations");
2.
In case of intensive use, it is recommended to clean the device every six months with dry
compressed air.
3.
In case of large amounts of dust, manual cleaning of the cooling system channels is
recommended.
ATTENTION
!
Blowing from too close a distance can damage electronic
components
12.
STORAGE CONDITIONS
Preserved and packaged welding set can be stored according to the State Standard
for 5 years
.
The source used should be stored in a dry enclosed room at a temperature not below 5
°C
. The room
must not contain vapour from acids or other chemically active substances.