Security and Logins
4-3
9664-A2-GB20-00
March 2000
"
Procedure
To limit asynchronous terminal access to the menu-driven user interface:
1. Select the Communication Port options.
Main Menu
→
Configuration
→
Management and Communication
→
Communication Port
2. Set the following configuration options, as appropriate.
To . . .
Set the configuration option . . .
Require a login
Login Required to Enable.
NOTE: User ID and password combinations
must be defined. See
Creating a Login
.
Limit the effective access level to
Level-3 or Level-2
Port Access Level to Level-2 or Level-3.
NOTE: Regardless of a user’s login access
level, a user cannot operate at a level higher
than the access level specified for the port
(e.g., if a user has a Level-1 login and Level-2
port access has been set, the Level-1 user
can only operate as a Level-2 user).
If you are going to allow Level-1 users to
configure the unit, keep the access at Level-1.
NOTE:
See
Resetting the Unit and Restoring Communication
in Chapter 6,
Troubleshooting, should you be locked out inadvertently.
3. Save your changes.