Troubleshooting
6-8
9664-A2-GB20-00
March 2000
Table 6-1.
Alarm Conditions (2 of 3)
Alarm Condition
What To Do
What It Indicates
LMI Down,
frame relay link
2
The Local Management
Interface is down for the
specified frame relay link.
For the network data port:
H
If LMI was never up, verify
that the LMI Protocol setting
reflects the LMI type being
used.
H
If LMI was never up:
H
Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.
If all of the above have been
verified and the physical link is
not in Alarm, contact your
network provider.
For user data port:
H
Check that the DTE cable is
securely attached at both
ends.
H
Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.
H
Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:
– Check the attached device.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
LOS at Network 1
A Loss of Signal (LOS)
condition is detected on the
leased line BRI S/T network
interface when it is not
transmitting INFO3 or
receiving INFO4.
H
Network cable problem.
H
No signal is being
transmitted at the far-end
FrameSaver unit.
H
T1 facility problem.
H
DSU(NT1) or leased-line
network facility problem.
H
Check that the network cable
is securely attached at both
ends.
H
Contact your network provider.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network data port, Network 1.
– Port-1. The frame relay link associated with the user data port.
Summary of Contents for FrameSaver SLV 9664
Page 1: ...FrameSaver SLV 9664 USER S GUIDE Document No 9664 A2 GB20 00 March 2000 ...
Page 130: ...Operation and Maintenance 5 36 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Page 150: ...Troubleshooting 6 20 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Page 186: ...Menu Hierarchy A 4 9664 A2 GB20 00 March 2000 This page intentionally left blank ...