Configure Branch
9-25
3810-A2-GB30-30
September 1998
Dial Line
The Dial Line configuration options are used to
configure the modem for operation over dial lines.
Table 9-4 shows each Dial Line configuration option as
it appears on the LCD, with the Async Dial factory default
setting (the default value if the modem is just being
installed) shown following the colon (:) on the first line
and with all available selections listed on the second line.
Following this is a description of the configuration option,
a description of the available selections, and any
equivalent AT commands.
Table 9-4
(1 of 3)
Dial Line Configuration Options
Dial LineRate: 19200(V32t)
Nxt 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 2400(V22bis)
1200(V22) 1200(212A) 0–300(V21) 0–300(103J)
Dial Line Rate. This configuration option determines the modem’s data rate and modulation scheme for operation on dial
lines. Online changes do not take effect until a disconnect occurs.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates
using V.32terbo, V.32bis, or V.32 modulation at the data rate selected. The modem can be forced by the remote modem
to a lower data rate.
2400(V22bis), 1200 (V22), 1200(212A) – Modem operates using the modulation and data rate selected.
0–300(V21), 0–300(103J) – Modem operates in full-duplex, Asynchronous mode. These data rates do not support V.42
or MNP
t
error control.
The factory default is 19200(V32t).
AT command for Dial Line Rate is S-register S41 = n, where n is:
1 = 14,400 (V.32bis)
7 = 1200 (V.22)
2 = 12,000 (V.32bis)
8 = 1200 (212A)
3 = 9600 (V.32bis/V.32)
10 = 0–300 (V21)
4 = 7200 (V.32bis)
11 = 0–300 (103J)
5 = 4800 (V.32bis/V.32)
20 = 19,200 (V.32terbo; default)
6 = 2400 (V.22bis)
21 = 16,800 (V.32terbo)
V32bis Automode: Enable
Nxt
Enable
Disable System 85
Enable – The modem automatically adapts to the modulation scheme and line rate of the remote modem. However, the
maximum data rate the modem uses is determined by the Dial Line Rate configuration option. Bell 103J protocol is used
for data rates of 0–300 bps.
Disable – Connection fails if the remote modem does not support the selected modulation.
System 85 – Modifies parameters used by the connection process. Specify System 85 only if your modem is in a
modem pool attached to a System 85 Private Branch Exchange (PBX).
The factory default is Enable.
AT command is S-register S78 = n, where n is 0 for Enable,1 for Disable, or 2 for System 85.
Summary of Contents for COMSPHERE 3800 Series
Page 9: ...COMSPHERE 3800 Series Modems G September 1998 3810 A2 GB30 30 ...
Page 15: ...COMSPHERE 3800 Series Modems vi September 1998 3810 A2 GB30 30 ...
Page 47: ...COMSPHERE 3800 Series Modems 4 16 September 1998 3810 A2 GB30 30 ...
Page 61: ...COMSPHERE 3800 Series Modems 7 6 September 1998 3810 A2 GB30 30 ...
Page 69: ...COMSPHERE 3800 Series Modems 8 8 September 1998 3810 A2 GB30 30 ...
Page 125: ...COMSPHERE 3800 Series Modems 11 4 September 1998 3810 A2 GB30 30 ...
Page 195: ...COMSPHERE 3800 Series Modems H 2 September 1998 3810 A2 GB30 30 ...
Page 205: ...COMSPHERE 3800 Series Modems Glossary 10 September 1998 3810 A2 GB30 30 ...
Page 212: ...00282600 See page 12 10 Set Admin PsWd ...
Page 213: ... 3810 A2 GB30 30 3810 A2 GB30 30 ...