Safety Instructions
B
3810-A2-GB30-30
September 1998
Important Safety Instructions
1.
Read and follow all warning notices and instructions marked on the product or included in the
manual.
2.
This product is intended to be used with a three-wire grounding type plug – a plug which has
a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe
operation. Do not defeat the purpose of the grounding type plug by modifying the plug or
using an adapter.
Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the
presence of earth ground. If the receptacle is not properly grounded, the installation must not
continue until a qualified electrician has corrected the problem.
If a three-wire grounding type power source is not available, consult a qualified electrician to
determine another method of grounding the equipment.
3.
Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of
the product and to protect it from overheating, these slots and openings must not be blocked
or covered.
4.
Do not allow anything to rest on the power cord and do not locate the product where persons
will walk on the power cord.
5.
Do not attempt to service this product yourself, as opening or removing covers may expose
you to dangerous high voltage points or other risks. Refer all servicing to qualified service
personnel.
6.
General purpose cables are provided with this product. Special cables, which may be required
by the regulatory inspection authority for the installation site, are the responsibility of the
customer.
7.
When installed in the final configuration, the product must comply with the applicable Safety
Standards and regulatory requirements of the country in which it is installed. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.
8.
A rare phenomenon can create a voltage potential between the earth grounds of two or more
buildings. If products installed in separate buildings are interconnected, the voltage potential
may cause a hazardous condition. Consult a qualified electrical consultant to determine
whether or not this phenomenon exists and, if necessary, implement corrective action prior to
interconnecting the products.
In addition, if the equipment is to be used with telecommunications circuits, take the following
precautions:
–
Never install telephone wiring during a lightning storm.
–
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
–
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
–
Use caution when installing or modifying telephone lines.
–
Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
–
Do not use the telephone to report a gas leak in the vicinity of the leak.
Summary of Contents for COMSPHERE 3800 Series
Page 9: ...COMSPHERE 3800 Series Modems G September 1998 3810 A2 GB30 30 ...
Page 15: ...COMSPHERE 3800 Series Modems vi September 1998 3810 A2 GB30 30 ...
Page 47: ...COMSPHERE 3800 Series Modems 4 16 September 1998 3810 A2 GB30 30 ...
Page 61: ...COMSPHERE 3800 Series Modems 7 6 September 1998 3810 A2 GB30 30 ...
Page 69: ...COMSPHERE 3800 Series Modems 8 8 September 1998 3810 A2 GB30 30 ...
Page 125: ...COMSPHERE 3800 Series Modems 11 4 September 1998 3810 A2 GB30 30 ...
Page 195: ...COMSPHERE 3800 Series Modems H 2 September 1998 3810 A2 GB30 30 ...
Page 205: ...COMSPHERE 3800 Series Modems Glossary 10 September 1998 3810 A2 GB30 30 ...
Page 212: ...00282600 See page 12 10 Set Admin PsWd ...
Page 213: ... 3810 A2 GB30 30 3810 A2 GB30 30 ...