Troubleshooting
C-3
3810-A2-GB30-30
September 1998
Table C-3
(2 of 2)
Modem – VF Connection
Symptom
Action
Originate Mode
Verify that the modem’s DTE Dialer configuration option is set to the correct setting: either AT,
DTR Dialing, V.25bis Async, V.25bis Bisync, or V.25bis HDLC.
Modem does not go
off-hook and begin
dialing
If using AT Dialing, refer to the Table C-2, Modem – DTE Connection.
If using DTR Dialing, verify the telephone number stored in directory location 1, and verify that
the DTE is raising DTR from Off to ON to initiate a dial.
If using V.25bis Async, verify that the correct character format is set to 7 data bits with even
parity and 1 stop bit, and the carriage return and line feed are used as command terminators.
If using V.25bis Bisync, verify that the correct character format uses two synchronous control
characters and a start-of-text control character before the text block and an end-of-text control
character after the text block.
If using V.25bis HDLC, verify that the correct character format uses flag, address, and control
characters before the text block and a frame sequence check and flag after the text block.
Modem dials but does
not connect
If the modem is operating behind a PBX, verify if a 9 and comma are needed before the
telephone number.
Verify whether Tone or Pulse dialing is needed.
Verify if one modem is configured for Error Control or Disconnect and the other modem is
configured for no Error Control. Try calling in Buffer mode.
If both modems use V.32bis or V.32 modulation, set the modem’s V.32bis Train configuration
option to Long.
Intermittent disconnects,
high error rates, or
excessive
retransmissions
Perform an End-to-End test. Refer to the Pattern section of Chapter 8, Test Branch.
Modem establishes and
disconnects a call
You may have a poor VF connection. Disconnect and dial again.
The remote modem may have encountered an EC Disconnect, where the modem is
configured to establish a call using error correction. If the modems cannot negotiate EC, then
a disconnect occurs.
The remote modem may be in a forced Error Control mode (disconnect if there is no error
control). Reconfigure your modem to V.42/MNP or Buffer and try again.
Check the LCD to verify the reason for disconnect.
Perform a Local Analog Loopback test.
High error rates occur
when running a local
loopback or self-test
Incoming rings can cause data errors during a loopback test. Abort the test, disconnect the
modular VF cord, and restart the test.
Summary of Contents for COMSPHERE 3800 Series
Page 9: ...COMSPHERE 3800 Series Modems G September 1998 3810 A2 GB30 30 ...
Page 15: ...COMSPHERE 3800 Series Modems vi September 1998 3810 A2 GB30 30 ...
Page 47: ...COMSPHERE 3800 Series Modems 4 16 September 1998 3810 A2 GB30 30 ...
Page 61: ...COMSPHERE 3800 Series Modems 7 6 September 1998 3810 A2 GB30 30 ...
Page 69: ...COMSPHERE 3800 Series Modems 8 8 September 1998 3810 A2 GB30 30 ...
Page 125: ...COMSPHERE 3800 Series Modems 11 4 September 1998 3810 A2 GB30 30 ...
Page 195: ...COMSPHERE 3800 Series Modems H 2 September 1998 3810 A2 GB30 30 ...
Page 205: ...COMSPHERE 3800 Series Modems Glossary 10 September 1998 3810 A2 GB30 30 ...
Page 212: ...00282600 See page 12 10 Set Admin PsWd ...
Page 213: ... 3810 A2 GB30 30 3810 A2 GB30 30 ...