-19-
RS485 SETUP
Use the following procedure to configure the RS485
setup when you want to use the system controller to
control the camera (pan, tilt, etc.) via the camera's data
port.
1. Display the setup menu (page 26), move the cursor
to RS485 SETUP
O
, and then press the CAM (SET)
button.
This will display the RS485 setup menu.
2. Check the unit number. (page 12)
The UNIT NUMBER item shows the unit number
specified by DIP Switch 1. The factory default unit
number is 1.
If DIP Switch 1 specifies 1 to 96 as the unit number,
move the cursor to UNIT NUMBER and then tilt the
joystick left or right to select a unit number (1 to 96).
Note:
It is not necessary to configure the RS485 SETUP
menu SUB ADDRESS setting.
3. Move the cursor to BAUD RATE, and then tilt the joy-
stick left or right to select a baud rate setting.
Tilting the joystick cycles through the baud rate
(transmission speed) display in the sequence shown
below. (unit: bits/s) The factory default setting is
19200.
4. Move the cursor to DATA BIT, and then tilt the joy-
stick left or right to select a data bit setting (7 or 8).
The factory default setting is 8.
5. Move the cursor to PARITY CHECK, and then tilt the
joystick left or right to select a parity bit setting
(NONE, ODD, EVEN).
The factory default setting is NONE.
6. Move the cursor to STOP BIT, and then tilt the joy-
stick left or right to select a stop bit setting (1 or 2).
The factory default setting is 1.
7. Move the cursor to XON/XOFF, and then tilt the joy-
stick left or right to select an XON/XOFF setting.
The factory default setting is NOT USE.
NOT USE:
Disables X ON/X OFF data flow control.
USE:
Enables X ON/X OFF data flow control.
8. Move the cursor to WAIT TIME, and then tilt the joy-
stick left or right to select a wait time setting.
The wait time is the time that the camera should wait
before resending data when no receive acknowl-
edgement (ACK) is returned after data is sent.
Tilting the joystick cycles through the wait time dis-
play in the sequence shown below. (unit: ms) The
factory default setting is OFF.
9. Move the cursor to ALARM DATA, and then tilt the
joystick left or right to select an alarm data send
mode setting.
POLLING:
Sends alarm data in response to a
request by the system controller.
AUTO1:
Sends alarm data each time an alarm sig-
nal is input.
AUTO2:
Sends alarm data at five-second intervals.
This is the factory default setting.
Note:
When using the preset alarm (page 41), select
"AUTO1".
10. Move the cursor to DELAY TIME, and then tilt the
joystick left or right to select a delay time setting.
The delay time is the time is the time the camera
should wait before sending a receive acknowledge
(ACK). The delay time display changes in the
sequence shown below. (unit: ms) The factory
default setting is OFF.
This setting can be configured only when 2-line con-
figuration is selected by DIP Switch 2. (page 11)
* RS485 SETUP *
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET
1
-----
19200
8
NONE
1
NOT USE
OFF
AUTO2
OFF
2400 4800 9600 19200
OFF
↔
100MS
↔
200MS
↔
400MS
↔
1000MS
OFF
↔
100MS
Summary of Contents for WV-CS570/G
Page 59: ... 59 DEUTSCHE AUSGABE GERMAN VERSION DEUTSCH ...
Page 117: ... 117 VERSION FRANÇAISE FRENCH VERSION FRANÇAIS ...
Page 175: ... 175 ESPAÑOL VERSION ESPAÑOLA SPANISH VERSION ...
Page 233: ... 233 VERSION ITALIANA ITALIAN VERSION ITALIANO ...
Page 291: ... 291 êìëëäÄü ÇÖêëàü RUSSIAN VERSION êìëëäàâ ...
Page 349: ... 349 ...