71
■
Connection with the Camera Sites
●
Data Multiplexed Cameras
Connect data multiplexed cameras (or camera site equipment) to the Camera Input (CAMERA IN, 1 - 8) connectors on the
Camera Input Board in the Camera Control Cage (MXCONT).
Caution:
Make sure that the cable length between the camera site and the MXCONT is less than 900 m (3 000 ft) when using
RG-59/U, BELDEN 9259 or equivalent cable.
1
2
3
4
5
6
7
CAMERA
Receiver
●
RS-485 Cameras
For cameras equipped with RS-485 communication feature, this will lower signal loss and extend the distance as video
signal and data are transmitted separately.
Connect the video output of the camera (or camera site equipment) to the Through I/O connector on the Loop-Through
Board in the Camera Control Cage (MXCONT).
Connect RS-485 cable between camera and Data connector on the RS485 Data Board of the Camera Control Cage
(MXCONT).
Note:
If you use cables assembled from locally procured materials, it is important that only high quality, data grade cable,
suitable for RS-485 interface “shielded 4-wire twisted pair cable, BELDEN 9406 or equivalent, is used.
Low grade cable will result in unstable operation of the system.
RS485
A
A
T
B
A
R
B
G
A
T
B
A
R
B
G
A
T
B
A
R
B
G
1
2
3
1
2
3
4
THRU