48
o
Link Indicator (LINK)
Is on (green) when communication is established with
the Main CPU.
!0
Operate Indicator (OPERATE)
Is on (green) while the controller’s power is turned on.
!1
Alarm key (ALARM)
This key, in combination with the Numeric keys, is used
to select an alarm. To select an activated alarm, press
the Numeric keys, followed by the ALARM key.
!2
Alarm Acknowledge key (ACK)
Acknowledges an activated alarm.
To acknowledge the activated alarm, first select the
alarm by pressing the Numeric keys, followed by the
ALARM key. Select the desired alarm action number by
pressing the Numeric keys, then press the ACK key.
The ACK indicator will light.
After acknowledging the alarm, press the RESET key to
reset the alarm. The ACK indicator will go off.
!3
Alarm Reset key (RESET)
Cancels an activated alarm.
Press this key to reset an alarm activated in the current-
ly active unit.
Pressing this key while holding down the SHIFT key
cancels all currently activated alarms at a time (ALL
RESET).
Pressing RESET in the Camera Menu will reset the
parameter of a selected item or open the Special
Camera Menu when the cursor is positioned on SPE-
CIAL in the menu. Pressing it while holding down the
SHIFT key will restore all factory default settings.
!4
Alarm Arm key (ARM)
This key, in combination with the Numeric keys and
ALARM key, is used to arm or disarm cameras and
monitor for alarm response. Select an alarm number by
pressing the Numeric keys, followed by the ALARM
key. Then pressing this key repeatedly will enable or
disable the alarm activation with the selected alarm
input.
!5
Function keys (F1 - F6)
These keys provide access to camera attributes and
operating functions.
F1:
Reserved for future use.
F2:
Reserved for future use.
F3:
Pressing F3 while holding down the SHIFT key will
close the Camera Menu on the active monitor
screen (CMENU OFF).
F4:
Pressing F4 while holding down the SHIFT key will
open the Camera Menu on the active monitor
screen (CMENU ON).
F5:
Reserved for future use.
F6:
Pressing this key will select the mode for control-
ling selected camera function (CAM FUNC).
!65
Joystick Controller (L / R / UP / DOWN)
The joystick is used to manually operate the PAN/Tilt
Head, or move the cursor in the Camera Menu on the
active monitor screen.
UP:
Upward
DOWN: Downward
L:
Left
R:
Right
!7
Iris Control keys (IRIS, CLOSE / OPEN)
Close or open the lens iris of cameras equipped with
the specified lens.
When these keys are pressed at the same time, the lens
iris is reset to the factory default setting.
These keys are also used to turn on the camera site
accessories. Pressing the CLOSE key while holding
down the SHIFT key will turn on the housing wiper of the
camera until the keys are released (WIPER).
!8
Focus Control keys (FOCUS, NEAR / FAR)
Adjust the lens focus of cameras equipped with the
specified lens.
Pressing these keys at the same time will automatically
set the lens focus if the specified camera with the auto
focus feature is equipped.
!9
Zoom Control keys (ZOOM, WIDE / TELE)
These keys are used for zooming cameras equipped
with the specified lens.
@0
Area key (AREA)
This key, in combination with the Numeric keys, is used
to change the monitoring area. Access is limited to
super users. Access by regular operators is prohibited.
The function allows users to apply logical numbers to
monitors.
Pressing this key while holding down the SHIFT key will
turn on the user's auxiliary 1 switch of the Receiver
(AUX1 ON).
@1
Program Preset key (PGM PRESET)
This key, in combination with the Numeric keys and
CAMERA (ENTER) key, is used to save a preset posi-
tion of camera in a system equipped with the specified
cameras.
To save a preset position, move the camera to the posi-
tion to be preset and select a preset number by press-
ing the Numeric keys. Hold down this key, then press
the CAMERA (ENTER) key.
Pressing this key while holding down the SHIFT key will
turn on the user's auxiliary 2 switch of the Receiver
(AUX2 ON).