11. Setting Up Remote Control Functions
The functions of the wireless remote can be set on site.
(These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed,
the settings do not revert to the defaults.)
NOTE
The operation of the air conditioner can be impacted, depending on the settings made, so only service
personnel should make the settings.
Furthermore, making changes to these settings may cause actual operation to deviate from what is printed
in the Users Manual, so be sure to explain this to the customer fully.
Making Settings (Do with unit stopped)
(1) Holding down the Swing/Wind Dir OFF Timer
+ Mode Select buttons at the same time
for 4 or more seconds makes the Display switch to the setting screen. (See diagram below.)
(2) Use the Temperature setting buttons,
/
, to select the number of the item to be set.
(3) Use the ON Timer buttons,
/
, to change settings.
(4) The settings are saved with the Once/Every Day button. When this is done, the settings display of the LCD
changes from blinking to light.
(5)
(6)
If other settings are to be changed as well, repeat steps 2 to 4.
When all settings have been made, press the Start/Stop button.
Example: Operation mode setting screen
Item Number & Setting Item
Setting Content
Setting when
Shipped
1
Operation Mode
2
Flap Display
(No display)
(Note 1)
3
Select Fan Speed
(No display)
4
Display of Set Temperature
°C °F Setting Off (Note 2)
°C
5
Time Display
24 Hour (No Display) AM/PM
24 Hour
6
Ventilation Fan ON/OFF
Off (No Display)
OFF(Note 3)
On
30
18 – 30°C
18 – 30°C
18 – 30°C
Cool temp Max
7
18
18 – 30°C
Cool temp Min
8
30 (Note 4)
16 – 30°C
Heat temp Max
9
16
16 – 30°C
Heat temp Min
10
30
Dry temp Max
11
18
Dry temp Min
12
27
17 – 27°C
17 – 27°C
Auto temp Max
13
17
Auto temp Min
14
16
Address Setting Max Value
00 (ALL only) 01 – 31
06 (Note 5)
17
Heat temp Max ON/OFF
JP (Heater Max Temp Change Off)
EP (On)
JP
NOTE
(1)
(2)
(3)
(4)
(5)
While the unit is in the swinging mode (Swing/Wind Direction), the flap cannot be stopped in a desired position.
When Setting OFF is selected, "°C" is displayed on the LCD screen.
You can toggle between ON and OFF by pressing Ventilation for 4 seconds or more.
If the Heater Max ON/OFF setting is not changed to EP (ON), the setting change will not be reflected.
This is the number of addresses that can be set in the address change mode. Do not set it to 07 or above.
Item
Number
8-16
SM830194-04_Single_BigPAC.indb 16
2014/10/31 13:30:53
Summary of Contents for S-200PE1E8
Page 88: ...1 82 MEMO ...
Page 112: ...3 2 3 3 1 Outdoor Units Electric Wiring Diagram U 200PE1E8 U 250PE1E8 ...
Page 113: ...3 3 3 Schematic Diagram U 200PE1E8 U 250PE1E8 ...
Page 115: ...3 5 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Electric Wiring Diagram ...
Page 116: ...3 6 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Schematic Diagram ...
Page 117: ...3 7 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Electric Wiring Diagram ...
Page 118: ...3 8 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Schematic Diagram ...
Page 119: ...3 9 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Electric Wiring Diagram ...
Page 120: ...3 10 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Schematic Diagram ...
Page 129: ...4 9 4 4 3 Outdoor Unit Filter PCB FIL C906VH8 ...
Page 130: ...4 10 4 4 4 Outdoor Unit HIC Board HIC C906VH8 ...
Page 136: ... MEMO 4 16 ...
Page 154: ... MEMO 5 18 ...
Page 164: ... MEMO 6 10 ...
Page 180: ... MEMO 7 16 ...
Page 197: ...201411 ...