8-15. Before Requesting Service
Before requesting service, please check the followings.
Solution
Cause
Problem
The unit doesn’t work
even when is pressed
on the remote control.
The power to the indoor unit is not ON.
Make sure the power to the indoor unit is ON.
Is the Normal/Stop All switch in the Stop All
(See Page 8-4)position?
Switch it to the Normal position and cancel
operation.
Are the remote control’s batteries dead?
Change the batteries.
Is there a mismatch between the display lamp and
cooling/heating or is it set to something other than
Auto? (The operating lamp stays lit, while the timer
lamp and the standby lamp blink alternately.)
Change the operating mode.
Do the addresses match one another?
Check the addresses of the receiver and the
remote control. (See Page 8-8)
The air conditioner
starts and stops on its
own.
Has the timer been set to repeat?
Check the timer settings.(See Page 8-6)
“ ” is displayed on the
remote control when the
unit is stopped.
An error has occurred in the non-volatile memory.
Please contact your sales outlet.
Although the unit is for air conditioning only, either Auto or Heat is indicated
in the display.
Make settings to the remote control’s operation
mode display. (See the previous page.)
After putting the batteries in the remote control, even when it is operated,
the display does not change.
Press the Reset button on the remote control.
(See Page 8-5)
Make the settings when the remote control is
The timer cannot be set.
in Operation Display. (See Page 8-6)
If the problem persists even after you check the foregoing items, stop the unit, disconnect the power to the indoor
unit and contact the dealer where the product was purchased with the model number and problem you are having.
As it is dangerous, under no circumstances should you undertake repairs yourself.
Further, when the receiver’s lamps are blinking; please contact your retailer with that information.
8-16. How to Install the Wireless Remote Controller Receiver
1. Warning about Installation of Receivers
The wireless remote uses a very weak infrared light for its signal, which can result in the signal not being received
because of the following influences, so take care in where the unit is installed.
• Inverter or rapid-start type fluorescent lights. (Models without glow lamps)
• Plasma display or LCD televisions.
• Direct sunlight or other sources of bright light.
2. Warning about Installing Remote Controls
(1) If a remote control is to be operated from a remote control holder that is hung on a wall, turn on the lights in the
room as well as any electrical appliances and then check to make sure the air conditioner works with the remote
control in the location where it will be installed. If it works, continue with installation.
(2) If the air conditioner is to be switched from the main sensor to a remote control sensor, pay attention to the
following when installing.
• Locate where no warm or cold drafts will affect it.
• Locate in a place free from direct sunlight.
• Locate where it will not be affected by any other heat/cold source.
8-10
SM830194-04_Single_BigPAC.indb 10
2014/10/31 13:30:51
Summary of Contents for S-200PE1E8
Page 88: ...1 82 MEMO ...
Page 112: ...3 2 3 3 1 Outdoor Units Electric Wiring Diagram U 200PE1E8 U 250PE1E8 ...
Page 113: ...3 3 3 Schematic Diagram U 200PE1E8 U 250PE1E8 ...
Page 115: ...3 5 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Electric Wiring Diagram ...
Page 116: ...3 6 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Schematic Diagram ...
Page 117: ...3 7 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Electric Wiring Diagram ...
Page 118: ...3 8 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Schematic Diagram ...
Page 119: ...3 9 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Electric Wiring Diagram ...
Page 120: ...3 10 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Schematic Diagram ...
Page 129: ...4 9 4 4 3 Outdoor Unit Filter PCB FIL C906VH8 ...
Page 130: ...4 10 4 4 4 Outdoor Unit HIC Board HIC C906VH8 ...
Page 136: ... MEMO 4 16 ...
Page 154: ... MEMO 5 18 ...
Page 164: ... MEMO 6 10 ...
Page 180: ... MEMO 7 16 ...
Page 197: ...201411 ...