3.2.4 Installing/Replacing the Power Supply Unit
Function
PSU Type
Lower/Upper Input Voltage Range
Current
Input Frequency
PSU-S
Lower: 100 V AC to 130 V AC
1.4 A
50 Hz or 60 Hz
(for KX-TDE100)
Upper: 200 V AC to 240 V AC
0.8 A
PSU-M
Lower: 100 V AC to 130 V AC
2.5 A
(for KX-TDE100/
KX-TDE200)
Upper: 200 V AC to 240 V AC
1.4 A
PSU-L
Lower: 100 V AC to 130 V AC
5.1 A
(for KX-TDE200)
Upper: 200 V AC to 240 V AC
2.55 A
AC Inlet
Power Switch
AC Inlet
Power Switch
PSU-S
PSU-M/PSU-L
Battery Switch
Earth Terminal
Battery Switch
Earth Terminal
Battery Connector
Battery Connector
Accessories and User-supplied Items
Accessories (included):
Screws
´
4
User-supplied (not included):
Earthing wire, Back-up Battery Cable (KX-A228 for PSU-S and PSU-M, or
KX-A229 for PSU-L)
Note
•
For details about frame earth connection, refer to "3.2.5 Frame Earth Connection".
•
For details about backup batteries connection, refer to "3.2.6 Backup Battery Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950, CAN/CSA-C22.2 No.60950, and
AS/NZS60950; therefore a protective earth connection exists between the mains outlet ground and the PSU
case. To ensure the PBX chassis is safely grounded, it is essential that the PSU case be securely fastened to
the PBX chassis with the 4 screws provided with each PSU.
When installing or replacing a PSU, basic safety precautions should always be followed to reduce the risk of
fire, electric shock and injury to persons, including the following:
1.
Never install or replace a PSU during a lightning storm.
2.
Never install or replace a PSU in wet locations.
56
Installation Manual
3.2.4 Installing/Replacing the Power Supply Unit
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...