DIP Switch
Radio Signal Test Switch
Power Supply Select Switch
Channel Number Switch
Channel 1 Channel 2 Channel 3 Channel 4
Channel 0
ON
OFF
ON: From the AC Adaptor (KX-A11)/
Battery Box (PSZZTD142CE)
OFF: From the PBX
Note
If more than 1 CS is in Radio Signal Test mode, each CS must have a unique channel number.
4.
After setting the DIP switches, connect the CS to an AC adaptor/battery box using a power supply adaptor,
or connect it to the PBX.
WARNING
The AC adaptor should be connected to a vertically oriented or floor-mounted AC outlet. Do not
connect the AC adaptor to a ceiling-mounted AC outlet, as the weight of the adaptor may cause
it to become disconnected.
Notice
•
When using the KX-TDA0158, it is NOT recommended to conduct the site survey using the battery
box.
•
If the Power Supply Select switch is set to ON in step 3, connect the CS to an AC adaptor/battery
box. If it is set to OFF, connect the CS to the PBX.
Installation Manual
231
3.11.4 Before Site Survey
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...