Note
•
The no. 4 and no. 5 pins (Master) of the CS must be connected to a pair of pins on the DHLC/DLC
card. Then use 4 consecutive pairs of pins on the DHLC/DLC card, starting with the pins corresponding
to the Master, as in the example above.
•
When connecting multiple KX-TDA0158CE CSs to a DHLC/DLC card, make sure that the no. 4 and
no. 5 pins (Master) of adjacent CSs are at least 3 pairs of pins away on the card.
•
CS connections must be made within the same DHLC/DLC card.
•
When a wrong connection is made, satisfactory performance of the CS cannot be guaranteed. Check
the connection of CS and the PBX using the Maintenance Console. For information about how to view
CS information using the Maintenance Console, refer to "2.6.15 Utility—CS Information" in the PC
Programming Manual.
KX-TDA0141CE
DHLC8 Card
Cable
Maximum Distance
ø 0.4 mm:
222 m
ø 0.5 mm:
347 m
ø 0.6 mm:
500 m
CAT 5:
347 m
D1
D2
1
2
3
4
D1
D2
CS (RJ11)
Pin No.
Signal Name
Signal Name
DHLC/DLC card (Amphenol)
Accessories and User-supplied Items for the CS
Accessories (included):
Screws
´
2, Washers
´
2
User-supplied (not included):
RJ11 connector
Note
For details about DHLC card or DLC card, refer to "3.6.2 DHLC8 Card (KX-TDA0170)", "3.6.3 DLC8 Card
(KX-TDA0171)", or "3.6.4 DLC16 Card (KX-TDA0172)".
180
Installation Manual
3.9.7 Connecting a Cell Station to the PBX
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...