3.
Repeat steps 1 and 2 for other CSs, and relocate the CSs when necessary.
a.
Plan adjacent CS coverage areas so that areas meet where radio signal strength level is "7" to "9".
Channel no. 0
Channel no. 1
b.
Plan the CS coverage areas to meet for at least 2 CSs at any location in the installation site.
Channel no. 0
Channel no. 1
Channel no. 2
Channel no. 3
c.
Make sure that the radio signal strength level is greater than "3" at any location in the service area
required by the user.
Note
•
If a channel is set, the results of measurement for the 24 slots on the channel are saved each time.
If the same channel is set, the new results override the previous ones. Therefore, a measurement
of 5 channels
´
24 slots in total can be made.
•
If correct results cannot be obtained (e.g., there are many frame errors), change the location of the
CS and repeat the site survey to select the best location.