1.4 Specifications
1.4.1 General Description
Control Bus
Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slots)
Switching
Non-blocking
Power Input
PSU-S
100 V AC to 130 V AC; 1.4 A/200 V AC to 240 V AC; 0.8 A; 50
Hz/60 Hz
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50
Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50
Hz/60 Hz
External Battery
+36 V DC (+12 V DC
´
3, recommended maximum capacity is
28 Ah)
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
W
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Trunk
From 10
´
3-party conference call to 4
´
8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port RS-232C
1 (maximum 115.2 kbps)
RJ45 Port
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
Installation Manual
29
1.4.1 General Description
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...