CS Coverage Area
The example below shows the size of the coverage area of 1 CS if it is installed in an area with no obstacles.
Note
Radio signal strength levels are measured during the site survey (refer to "3.10.5 Site Survey").
Gray Zone:
Conversation will be
intermittent
Coverage Area
Radio signal strength level is
greater than "3".
(About 50 m to 60 m*
1
)
Good Coverage Area
Radio signal strength
level is greater than "8".
(About 30 m to 40 m*
2
)
Good sound quality
can be maintained.
Out of Service:
Cannot make/receive calls
A
B
A
B
Radio Signal Strength Levels
C
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
Level: 00
Level: 01 to 02
Level: 03 to 07
Level: 08 to 10
Level: 11 to 12
KX-TDA0151CN: About 35 m to 50 m
*
1
KX-TDA0151CN: About 20 m to 30 m
*
2
Site Survey Preparation
1.
Obtain a map and investigate the installation site.
a.
Check the obstacles (e.g., shelves, columns, and partitions).
b.
Check the materials of the structures (e.g., metal, concrete, and plywood).
c.
Check the layout and dimensions of the room, corridor, etc.
d.
Write down the above information on the map.
2.
Examine the service area required by the user on the map, referring to the following example.
a.
Draw the coverage area around a CS. Extend the coverage area 30 m to 60 m (20 m to 50 m for the
KX-TDA0151CN) in each direction, depending on the materials of the building structures and obstacles
in the installation site. Note that a CS cannot be installed outside a building.
Installation Manual
197
3.10.3 Site Planning
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...