2.4
Installation of Optional Cards and Unit
General Installation
91
2.4.7
SLT Message Waiting Lamp Adaptor Unit Connection
Name and Locations
Specifications
1. General Description
Capacity
Corresponding extensions
16
Control Method
CPU: One-chip microcomputer
Interface: 1-APT Interface
Power Supplies
Primary Power
Secondary
220 VAC – 240 VAC,
50 Hz / 60 Hz
Station Supply Voltage: + 85 V
Circuit Voltage: + 5 V, + 15 V
Connectors
Stations
DC Input/Output
Interface
50-pin Amphenol Connector
4-pin Connector
Side View
AC inlet
Power light
Ground terminal
Binders
DC input/output
Connector (TO SYSTEM)
Connector (TO EXTN)
connector