5.2
Wireless System Installation
DECT Installation
165
Note
•
To see the signal strength of more than one Cell Station, the channel for each Cell Station
needs to be set.
•
Up to eight Cell Stations can be surveyed at the same time. If more than one Cell Station is
in Radio Signal Test mode, each DIP-Switch channel must be different.
Connecting the AC Adaptor to the Cell Station
After setting the DIP-Switch, connect the AC Adaptor (KX-A11BS1: 230 VAC, 50 Hz) to the
Cell Station.
Note
Only use the AC Adaptor for the Site Survey.
Radio Signal Test using the PS
After locating the Cell Station(s) temporarily, execute the Radio Signal Test using the PS.
The PS scans whether there is a Cell Station that can link with on channel 0 right after entering
the Radio Signal Test mode. The channel to be scanned can be changed by pressing the
appropriate 0 through 9 keys.
1.
Set the PS Power Switch to ON while pressing
(Talk),
(Flash) and
at the same time.
Display: FUNCTION<0-4>
2.
Press .
•
To survey other slots, scroll by pressing
(Next) or
(Previous).
•
To survey other channels, enter the channel number (0 through 9).
Summary of Contents for KX-TD1232NL
Page 12: ...12 Table of Contents ...
Page 13: ...System Outline 13 Section 1 System Outline ...
Page 31: ...General Installation 31 Section 2 General Installation ...
Page 60: ...2 3 Connection 60 GeneralInstallation Features Guide References Background Music BGM ...
Page 114: ...2 9 System Data Clear 114 GeneralInstallation ...
Page 115: ...ISDN Installation 115 Section 3 ISDN Installation ...
Page 127: ...E M Installation 127 Section 4 E M Installation ...
Page 140: ...4 2 E M TIE Line Installation 140 E M Installation ...
Page 141: ...DECT Installation 141 Section 5 DECT Installation ...
Page 170: ...5 2 Wireless System Installation 170 DECT Installation ...
Page 171: ...Troubleshooting 171 Section 6 Troubleshooting ...
Page 178: ...6 1 Troubleshooting 178 Troubleshooting ...
Page 179: ...Index 179 Section 7 INDEX ...
Page 182: ...Index 182 ...