FP2 Analog Unit
Sample Program for Analog Output Hold Setting
12 - 6
12.2 Output Hold (Any Value) Setting Program
Sample program:
R 9010
F0 MV
DT 100
WY 0
,
,
F0 MV
DT 101
WY 1
,
,
F0 MV
DT 102
WY 2
,
,
F0 MV
DT 103
WY 3
,
,
R 9013
F0 MV
K
2
DT 30
,
,
F0 MV
K 2047
DT 31
,
,
F0 MV
K 2047
DT 32
,
,
F0 MV
K 4095
DT 33
,
,
F0 MV
K 4095
DT 34
,
,
F151 WRT K 0
K 5 K 17
DT 30
,
,
,
,
ED
Initial
setting
Always on
Output hold setting
ch 0 any value
Output hold
setting
ch 1 any value
ch 2 any value
ch 3 any value
ch 0 output value
ch 0 data
ch 1 output value
ch 1 data
ch 2 output value
ch 2 data
ch 3 output value
ch 3 data
Analog output hold data
(any value) setting
Analog output data Writing
is written to the shared memory addresses 17 and 21.
The 5-word data from data register DT30
Specifies the analog output
unit in slot no. 0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]