High
−
level Instructions
3
−
662
Description
The output value (word data) stored in the area specified by D is controlled based on whether or not the input
value (word data) specified by S3 falls within the dead-band bounded by the upper and lower limits set in S1
and S2.
The output value is determined based on the following conditions:
When the lower limit S1 is greater than the input value S3, the input value S3 minus the lower limit value S1 is
stored in D as the output value.
When the upper limit S2 is less than the input value S3, the input value S3 minus the upper limit value S2 is
stored in D as the output value.
When Lower limit S1
Input value S3
Upper limit S2, zero is stored in D as the output value.
Output value D
In this range, zero is output.
Input value S3
Lower limit of
deadband S1
Upper limit of deadband S2
0
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
・
Error flag (R9008): Turns on for an instant when:
−
The area specified using the index modifier exceeds the limit.
−
S1 > S2.
・
Carry flag (R9009): Turns on for an instant when the calculated result is overflowed or
underflowed.
・
= flag (R900B):
Turns on when the input value is recognized as “0.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...