High
−
level Instructions
3
−
533
Outline
Outputs the pulses from the specified channel for the pulse output
according to the specified data table.
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
10
F174 SP0H , DT100 , K 0
S
n
Trigger
R10
DF
10
11
12
ST
R
10
DF
F174
(SP0H)
DT
100
K
0
S
Starting address of area containing the data table.
n
Channel for pulse output.
Operands
Operand
Relay
Timer/Counter Register
Index
register
Constant
Index
modifier
Operand
WX WY WR
SV
EV
DT
I
K
H
modifier
S
N/A N/A N/A
N/A
N/A
A
N/A
N/A N/A
A
n
N/A N/A N/A
N/A
N/A
N/A
N/A
A
A
N/A
Description
When the corresponding control flag is off and the execution condition is in the on state, pulses are output
from the specified channel (ch0 or ch2) based on the contents set for the data table in which the first address
is that specified by “S”.
For FP
Σ
For FP
−
X Ry type (AFPX
−
PLS)
Channel no.
Output
Output method
Channel no.
Output
Output method
ch0
Y0
CW
PLS
ch0
Cassete
Y100
CW
PLS
Y1
CCW
SIGN
Cassete
mounting part 1
Y101
CCW
SIGN
ch2
Y3
CW
PLS
ch1
Cassete
Y200
CW
PLS
Y4
CCW
SIGN
Cassete
mounting part 2
Y201
CCW
SIGN
FP
Σ
/FP
−
X
Pulse output
(with channel specification)
(Selectable data table control operation)
5
F174
(SP0H)
Availability
FP
Σ
/FP
−
X
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...