High
−
level Instructions
3
−
614
Flag conditions
Σ
Error flag (R9007):
Turns on and stays on when
Σ
Error flag (R9008):
Turns on for an instant when
−
There is an error in the control string specified by S1.
−
The direction of converted data is changed to the normal direction when the
conversion format specified by S1 is in decimal.
−
The size of the area for storing ASCII codes specified by N exceeds the
rated value when the conversion format specified by S1 is in hexadecimal.
(Rated value for 16
−
bit data: 4)
(Rated value for 32
−
bit data: 8)
−
The No. of the converted blocks specified by N is 0.
−
The size of the area for storing ASCII codes specified by N is 0.
−
The ASCII code to be converted exceeds the area.
−
The area specified using the index modifier exceeds the limit.