High
−
level Instructions
3
−
40
Description
S2 blocks of data stored in the data register starting from S1 are transferred into the EEPROM area specified
by D. At this time, the transferred data is handled in units of 1 block/64 words.
Precautions during programming
Values that can be specified by S1, S2 and D
Type
Memory area
yp
S1
S2
D
FP0 C10, C14, C16, FP
−
e
DT0 to DT1595
K1 to K10
K0 to K9
FP0 C32, SL1
DT0 to DT6080
K1 to K96
K0 to K95
FP0 T32
DT0 to DT16320
K1 to K256
K0 to K255
Volume of data that can be held in the EEPROM
Type
Volume that can be read
FP0 C10, C14, C16, FP
−
e
640 words
FP0 C32, SL1
6,144 words
FP0 T32
16,384 words
Data can be written to the EEPROM up to 10,000 times.
In order to prevent this instruction from being written to the EEPROM numerous times through erroneous
programming, it has been set up as a differential execution type of instruction (P13). When setting up the
program, however, please make sure that this instruction is not written to the EEPROM numerous times.
When the instruction is executed, the operation execution time will be approximately 5 ms longer for block (64
words).
This instruction should not be used in interrupt programs.
If the FP0R is used as the FP0, the execution time will be longer. (FP0 compatibility mode)
Comparative chart of execution time of FP0R in FP0 mode and FP0
No. of specified
blocks
Execution time of FP0 (Unit: ms)
Execution time of FP0R in FP0
compatibility mode (Unit: ms)
1
5
100
2
10
100
4
20
100
8
40
100
16
80
100
32
160
100
33
165
200
40
205
200
Note that the execution time of the FP0R in FP0 mode is longer as shown in the above chart.
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
・
Error flag (R9008): Turns on for an instant when:
−
The number specified by S1 does not exist in the memory area.
−
The area specified by S2 exceeds the limit of the memory area.
−
The area is exceeded when blocks specified by D and subsequent
parameters are transferred.
FP0/FP
−
e
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...