Relays, Memory Areas and Constants
1 - 32
Available range of link relays
The available range of link relays varies depending on the type of network and the
combination of units. The available range and number of points must be specified
separately for each network.
For MEWNET
−
W and MEWNET
−
P:
A maximum of 1,024 points are available with one link unit. The available range is from
L0 to L63F for the first unit (PC Link 0), and from L640 to L127F to the second unit (PC
Link 1).
For MEWNET
−
W2
A maximum of 4,096 points can be used per link unit. Please set the range of use at
the MEWNET
−
W2 settings menu.
With the FP2SH, the range between L0 and L639F can be specified. When used with
MEWNET
−
W the range between L0 and L127F cannot be used.
With the FP2, the range between L0 and L127F can be specified. Also, the internal
relay can be used in place of the link relay by setting the MEWNET
−
W2 setting menu.
However, when used with MEWNET
−
W the range between L0 and L127F cannot be
used with MEWNET
−
W2.
For MEWNET
−
H:
A maximum of 10,240 points can be used. Please set the range to be used with the
MEWNET
−
H link setting software.
With the FP10SH, the range from L0 to L639F can be used.
If used in conjunction with a MEWNET
−
W or MEWNET
−
P link unit, be aware that the
range from L0 to L127F cannot be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...