Pulse output channels and areas used
Channel
No.
Output Output type
Position
control
starting
input
Pulse
output
instruction
flag
Elapsed
value area
Target
value
area
Correction
speed of
initial
speed
Deceleration
minimum
speed
Acceleration
forbidden
area starting
position
ch0
Y0
CW
PLS
X0
DT90052
R9120
DT90400
DT90402 DT90406 DT90407 DT90408
ch0
Y1
CCW SIGN
DT90052
bit6
R9120
DT90400
DT90401
DT90402
DT90403 DT90406
DT90407
DT90408
DT90409
ch1
Y2
CW
PLS
X1
DT90052
R9121
DT90410
DT90412 DT90416 DT90417 DT90418
ch1
Y3
CCW SIGN
DT90052
bit6
R9121
DT90410
DT90411
DT90412
DT90413 DT90416
DT90417
DT90418
DT90419
ch2
Y4
CW
PLS
X2
DT90052
R9122
DT90420
DT90422 DT90426 DT90427 DT90428
ch2
Y5
CCW SIGN
DT90052
bit6
R9122
DT90420
DT90421
DT90422
DT90423 DT90426
DT90427
DT90428
DT90429
ch3
Y6
CW
PLS
X3
DT90052
R9123
DT90430
DT90432 DT90436 DT90437 DT90438
ch3
Y7
CCW SIGN
DT90052
bit6
R9123
DT90430
DT90431
DT90432
DT90433 DT90436
DT90437
DT90438
DT90439
Setting the data table
S
S+1
Control code
S+2
S+3
Initial speed
(Hz)
Velocity range (Frequency) (Hz)
S+4
S+5
Target speed
(Hz)
Velocity range (Frequency) (Hz)
1Hz to 50kHz [K1 to K50000 (Unit: Hz)]
S+6
S+7
Acceleration time
(ms)
Acceleration time up to the max. speed 50kHz.
Acceleration time range (ms) K1 to K32760 (Unit: ms)
S+8
Deceleration time Deceleration time from the max. speed 50kHz.
S+8
S+9
Deceleration time
(ms)
Deceleration time from the max. speed 50kHz.
Deceleration time range (ms) K1 to K32760 (Unit: ms)
S+10
S+11
Target value
(No. of pulses)
Target value range
K
−
2,147,483,648 to K2,147,483,647
Note the following characteristics according to the specified initial speed.
(1) When the initial speed is 1 or higher, and lower than 46Hz, the control up to the maximum frequency to the
degree of 10kHz can be performed.
If the frequency is higher than that, the speed error will be larger.
(2) When the initial speed is 46 or higher, and lower than 184Hz, the control up to 50kHz can be performed.
(3) When the initial speed is 184 or higher, the control up to 50kHz can be performed.
The speed error around 50kHz will be smallest.
Change of speed during pulse output
(1) If the target value is set to a value larger than 50kHz, it will be corrected to 50kHz.
(2) If the elapsed value crosses over the acceleration forbidden area starting position during accelerating,
acceleration cannot be performed.
For information on the acceleration forbidden area starting position, refer to the special registers.
(3) For deceleration, the speed cannot be lower than the deceleration minimum speed.
For information on the deceleration minimum speed, refer to the special registers.
FP0R
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...