Basic Instructions
2
−
104
Specifying control data
S1: Specifying the control functions and interrupt types
8 7
4 3
0
12 11
15
S1
. .
. .
. .
. .
Bit position
Selection of control function
H00: Interrupt “enabled/disabled” control
H01: Interrupt trigger reset control
Interrupt type selection
H00: INT 0 to INT 7
H02: INT 24 (10ms units)
H03: INT 24 (0.5ms units)
Set S1 = H0 to specify enable or disable for the execution of INT0 through INT7.
Set S1 = H100 to clear interrupts INT0 through INT7.
Set S1 = H2 (for units of 10ms) to set the time interval for INT24.
Set S1 = H3 (for units of 0.5ms) to set the time interval for INT24.
Precautions during programming
The inputs that can be actually used as an interrupt input are different depending on the models. (Refer to the
table below.)
Interrupt
P
N
Interrupt input
p
Program No.
FP0/FP
−
e
FP
Σ
/FP0R
FP
−
X Ry
FP
−
X Tr
INT0
X0
X0
X0
X0
INT1
X1
X1
X1
X1
INT2
X2
X2
X2
X2
INT3
X3
X3
X3
X3
INT4
X4
X4
X4
X4
INT5
X5
X5
X5
X5
INT6
—
X6
X6
X6
INT7
—
X7
X7
X7
INT8
—
—
X100
—
INT9
—
—
X101
—
INT10
—
—
X102
—
INT11
—
—
X200
—
INT12
—
—
X201
—
INT13
—
—
X202
—
INT24
Periodical interrupt
Note) When using the high
−
speed counter
−
initiated interrupt program, the counting performance
of the high
−
speed counter may be decrement at the moment of the start
−
up of the interrupt
program.
FP0/FP0R/FP
−
e/FP
Σ
/FP
−
X
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...