High
−
level Instructions
3
−
545
Setting the data table
[S]
Control code
(
*
1)
[S]
Control code
(
*
1)
[S+2]
Composite speed
Initial speed Fmin(Hz)
(
*
2)
S tti
[S+4]
Composite speed
Maximum speed Fmax(Hz)
(
*
2)
Setting area
[S+6]
Acceleration/Deceleration time T (ms)
(
*
3)
Designated with
user program
[S+8]
X
−
axis (CH0)
Target value (Movement distance)
(
*
4)
user program
[S+10]
Y
−
axis (FP
Σ
: CH2, FP
−
X: CH1)
Target value (Movement distance)
(
*
4)
[S+12]
X
−
axis (CH0) component speed
Initial speed Fxmin
[S+14]
X
−
axis (CH0) component speed
Maximum speed Fxmax
(
*
5)
Operation result
[S+16]
Y
−
axis (FP
Σ
: CH2, FP
−
X: CH1) component speed
Initial speed Fymin
(
*
5)
Operation result
storage area
[S+18]
Y
−
axis (FP
Σ
: CH2, FP
−
X: CH1) component speed
Maximum speed Fymax
Parameters for each
i
t
[S+20]
X
−
axis (CH0) frequency range
(
*
6)
axis component,
calculated due to
[S+21]
Y
−
axis (FP
Σ
: CH2, FP
−
X: CH1) frequency range
(
*
6)
calculated due to
instruction execution,
[S+22]
X
−
axis (CH0) number of
acceleration/deceleration steps
(
*
7)
instruction execution,
are stored here.
[S+23]
Y
−
axis (FP
Σ
: CH2, FP
−
X: CH1) number of
acceleration/deceleration steps
(
*
7)
(
*
1): Specification of control code (specify with H constant)
Operation mode and output method
00: Incremental
CW/CCW
02: Incremental
PLS + SIGN (forward off / reverse on)
03: Incremental
PLS + SIGN (forward on / reverse off)
10: Absolute
CW/CCW
12: Absolute
PLS + SIGN (forward off / reverse on)
13: Absolute
PLS + SIGN (forward on / reverse off)
H
□ □ □ □ □ □ □ □
0: Fixed
Duty (on width)
0: Duty 1/2 (50%)
1: Duty 1/4 (25%)
0: Fixed
S+1
S
(
*
2): Composite speed (Initial speed, Maximum speed) (Hz) <K constant>
1.5Hz to 100kHz [K1 to K100000]
However, 1.5Hz is for an angle of 0deg or 90deg only.
Also, specify K1 when specifying 1.5 Hz.
If the component speed drops lower than the minimum speed for each frequency range, then the
speed will become the corrected component speed, so be careful. (See
*
6)
When simultaneously using a high
−
speed counter, periodical interrupt or PLC link, do not set to 60kHz
or higher.
If initial speed is set equal to maximum speed, pulses will be output with no acceleration/deceleration.
Set the composite speed so that component speed of each axis is 1.5 Hz or greater.
Composite speed (initial speed): 30 kHz or lower
FP
Σ
C32T2/FP
−
X
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...