High
−
level Instructions
3
−
121
Outline
Adds 1 to BCD data that expresses an 8-digit decimal number (8-digit
BCD H code).
For the FP0R/FP
Σ
/FP
−
X/FP0/FP
−
e, the P type high
−
level instruction
“P56 (PDB+1)” is not available.
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
10
F56 DB+1 , DT 0
D
Trigger
R0
10
11
ST
R
0
F 56
(DB+1)
DT
0
D
Lower 16-bit area for 8-digit BCD data to be increased by 1
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
Operand
WX WY WR WL
(
*
1)
SV
EV
DT LD
(
*
1)
FL
(
*
2)
IX
(
*
3)
IY
K
H
Index
modifier
D
N/A
A
A
A
A
A
A
A
A
A
N/A
N/A N/A
A
(
*
1) This cannot be used with the FP0 and FP
−
e.
(
*
2) This cannot be used with the FP0, FP
−
e, FP0R, FP
Σ,
FP
−
X.
(
*
3) With the FP0R, FP
Σ
, FP
−
X, FP2, FP2SH, and FP10SH, this is I0 to IC.
Explanation of example
Adds 1 to the contents (8
−
digit BCD data) of data registers DT1 and DT0 when trigger R0 turns on.
Contents of
DT1
Higher 16 bits Lower 16 bits
Contents of
DT0
+1
Store to DT1
Store to DT0
The specified data area and the
following data area are handled
together as 32
−
bit data.
F56
P56
(PDB+1)
(DB+1)
8-digit BCD data increment
[(D+1, D) + 1
→
(D+1, D)]
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...