High
−
level Instructions
3
−
94
Description
Multiplies the 32-bit data or 32-bit equivalent constant specified by S1 and the one specified by S2 when the
trigger turns on.
The multiplied result is stored in D+1 and D (32-bit area).
Multiplicand data
Trigger turns on
Result (32-bit)
S1:
lower 16-bit
S1+1: higher 16-bit
D
D+1
×
Multiplier data
S2:
lower 16-bit
S2+1: higher 16-bit
The multiplied result is stored in the 32-bit area (2 words).
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
・
Error flag (R9008): Turns on for an instant when:
−
The area specified using the index modifier exceeds the limit.
−
The calculated result exceeds the 32-bit area specified by D.
・
= flag (R900B):
Turns on for an instant when the calculated result is recognized as “0”.
Precautions during programming
Keep the calculated result D within the range K
−
2147483648 to K2147483647.