5-170
FP1/FP-M/FP2/FP2SH/FP10SH/FP3
Address
Name
Description
R9050
MEWNET-W/-P link
transmission error flag
[W/P LINK 1] for FP3/
FP10SH
[W LINK 1] for FP2/FP2SH
When using MEWNET-W link unit or MEWNET-P link
unit:
- turns on when transmission error occurs at link 1.
- turns on when there is an error in the link area settings.
R9051
MEWNET-W/-P link
transmission error flag
[W/P LINK 2] for FP3/
FP10SH
[W LINK 2] for FP2/FP2SH
When using MEWNET-W link unit or MEWNET-P link
unit:
- turns on when transmission error occurs at link 2.
- turns on when there is an error in the link area settings.
R9052
MEWNET-W/-P link
transmission error flag
[W/P LINK 3] for FP3/
FP10SH
[W LINK 3] for FP2/FP2SH
When using MEWNET-W link unit or MEWNET-P link
unit:
- turns on when transmission error occurs at link 3.
- turns on when there is an error in the link area settings.
R9053
MEWNET-W/-P link
transmission error flag
[W/P LINK 4] for FP2/
FP10SH
[W LINK 4] for FP2SH
When using MEWNET-W link unit or MEWNET-P link
unit:
- turns on when transmission error occurs at link 4.
- turns on when there is an error in the link area settings.
R9054
MEWNET-W/-P link
transmission error flag
[W/P LINK 5] for FP2/
FP10SH
[W LINK 5] for FP2SH
When using MEWNET-W link unit or MEWNET-P link
unit:
- turns on when transmission error occurs at link 5.
- turns on when there is an error in the link area settings.
R9055
MEWNET-H link
transmission error flag
[H LINK 1]: for FP3/
FP10SH
When using MEWNET -H link unit:
- turns on when transmission error occurs at H link 1.
- turns on when there is an error in the link area settings.
R9056
MEWNET-H link
transmission error flag
[H LINK 2]: for FP3/
FP10SH
When using MEWNET -H link unit:
- turns on when transmission error occurs at H link 2.
- turns on when there is an error in the link area settings.
R9057
MEWNET-H link
transmission error flag
[H LINK 3]: for FP3/
FP10SH
When using MEWNET-H link unit:
- turns on when transmission error occurs at H link 3.
- turns on when there is an error in the link area settings.
R9058
Remote I/O transmis-sion
error flag (master 1)
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
When using MEWNET -F (remote I/O) system:
- turns on when transmission error occurs on master 1.
- turns on when there is an error in the settings.
R9059
Remote I/O transmis-sion
error flag (master 2)
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
When using MEWNET -F (remote I/O) system:
- turns on when transmission error occurs on master 2.
- turns on when there is an error in the settings.
R905A
Remote I/O transmission
error flag (master 3)
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
When using MEWNET -F (remote I/O) system:
- turns on when transmission error occurs on master 3.
- turns on when there is an error in the settings.
R905B
Remote I/O transmis-sion
error flag (master 4)
(Available PLC: FP2/
FP2SH/FP3/FP10SH)
When using MEWNET -F (remote I/O) system:
- turns on when transmission error occurs on master 4.
- turns on when there is an error in the settings.
R905C to
R905F
Not used
-
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-E
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...