46
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
47
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
CAUTION
Danger of water pipes freezing in outside temperatures below 0 °C
If the heating circuit in the compact system is filled with water and the outside temperature falls
below 0 °C, the risk exists in the compact system that the water pipes may freeze. This can
cause a lot of damage to the device.
The client should therefore ensure the absence of frost by taking
one
of the following
measures:
►
Operate the heating circuit using a food-safe antifreeze mixture (propylene glycol).
►
Provide an additional cabinet heating in the compact device, to prevent the heating
circuit from freezing up.
►
Empty the heating circuit by using a built-in device (manually or automatically) before
freezing starts.
4.6.3.1 Components
Compact system - Model B8
A
1
2
3
D
8
9
11
10
B
7
4 5 6
C
E
F
12
13
16
14
17
15
18
A Exterior view
1 Upper device panelling
2 Valve covers
3 Front panel
B Top view (with opened device panelling)
and
C Detailed view of overload protection
4 6 litre expansion vessel
5 Flow monitor
6 E-heating element heat pump
7 Overload protection (x 2)
D Front view (with opened front panel)
8 Electronic PCB
9 FI protection switch
10 Heat exchanger
11 Circulating water pump
E Side elevation
and
F Rear view
12 Safety valve (only visible without cover)
13 Quick vent valve (only visible without cover)
14 Manometer (only visible without cover)
15 Dirt catcher with 2 stop valves (only visible without
cover)
16 Water inflow
17 Water return
18 Cable glands
Split systems with hydro-module / HT series / F Generation
HT series
Single phase (230 V / 50 Hz), heating only
Three-phase (400 V / 50 Hz), heating only
Hydro-module
WH-SHF09F3E5
WH-SHF12F6E5
WH-SHF09F3E8
WH-SHF12F9E8
Outdoor unit
WH-UH09FE5
WH-UH12FE5
WH-UH09FE8
WH-UH12FE8
Set (hydro- outdoor unit)
KIT-WHF09F3E5
KIT-WHF12F6E5
KIT-WHF09F3E8
KIT-WHF12F9E8
Model
B6
B6
B6
B6
Heating capacity at +7 °C (A7/W35)
kW
9.00
12.00
9.00
12.00
COP at +7 °C (A7/W35)
4.64
4.46
4.64
4.46
Heating capacity at +2 °C (A2/W35)
kW
9.00
12.00
9.00
12.00
COP at +2 °C (A2/W35)
3.45
3.26
3.45
3.26
Heating capacity at -7 °C (A–7/W35)
kW
9.00
12.00
9.00
12.00
COP at -7 °C (A–7/W35)
2.74
2.52
2.74
2.52
Heating capacity at +7 °C (A7/W65)
kW
9.00
12.00
9.00
12.00
COP at +7 °C (A7/W65)
2.27
2.22
2.27
2.22
Heating capacity at +2 °C (A2/W65)
kW
9.00
10.30
9.00
10.30
COP at +2 °C (A2/W65)
1.89
1.84
1.89
1.84
Heating capacity at -7 °C (A–7/W65)
kW
8.90
9.60
8.90
9.60
COP at -7 °C (A–7/W65)
1.63
1.62
1.63
1.62
Energy efficiency class
1
at 35 / 55 °C
i
/
i
i
/
i
i
*
/
i
i
*
/
i
Hydro-module
Sound pressure level
dB(A)
33
33
33
33
Dimensions
H x L x W
mm
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
Weight
kg
46
47
47
48
Water-side connection
mm
28
28
28
28
High efficiency pump
Rotation speed stages
7
7
7
7
Power consumption (min./ max.)
W
38 / 100
40 / 106
38 / 100
40 / 106
Water flow rate (A7/W35)
l/min
25.8
34.4
25.8
34.4
Power of E-heating element
kW
3
6
3
9
Power consumption
kW
1.94
2.69
1.94
2.69
Operating and start up current
A
9.3
12.9
3.0
4.2
Max. power consumption on network connection 1 / 2
A
28.5 / 13.0
29.0 / 26.0
14.5 / 13.0
10.8 / 13.0
Recommended fuse for network connection 1 / 2
A
30 / 30
30 / 30
30 / 16
30 / 16
Recommended cable cross section for network connection 1 / 2 mm²
3 x 4.0 or 6.0 / 3 x 4.0
3 x 4.0 or 6.0 / 3 x 4.0
5 x 1.5 / 3 x 1.5
5 x 1.5 / 5 x 1.5
Outdoor unit
Sound pressure level
dB(A)
51
52
51
52
Dimensions
H x L x W
mm
1,340 x 900 x 320
1,340 x 900 x 320
1,340 x 900 x 320
1,340 x 900 x 320
Weight
kg
104
104
110
110
Line diameter
Fluid line
mm (inches)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
Gas line
mm (inches)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
Pre-filled refrigerant (R407C) / CO
2
-equivalent
kg / t CO
2
-Equ. 2.90 / 5.145
2.90 / 5.145
2.90 / 5.145
2.90 / 5.145
Connection distance
m
3 – 30
3 – 30
3 – 30
3 – 30
Nominal connection distance
m
7
7
7
7
Pre-filled connection distance
m
10
10
10
10
Additional coolant fill-up quantity (R407C)
g/m
70
70
70
70
Max. height difference IU/OU
m
20
20
20
20
Operating range
Outside temperature
°C
-20 to 35
-20 to 35
-20 to 35
-20 to 35
Water outlet temperature
°C
25 to 60
25 to 60
25 to 60
25 to 60
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
1 Energy efficiency class scale from A++ to G.
4.6.3 Compact system
The compact system consists of a device that is installed in the external area and can be con-
nected directly to the heating circuit. The operation is effected via wired remote controller inside
the building.
Summary of Contents for Aquarea B1