178
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Installation
179
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Installation
5. Connect the power cords 1 and 2 accordingly to mains connection 1 and 2 (
9
,
10
or
11
,
12
), according to the following installation example (see below) and the connection
diagram following it and take care to leave the ground connector longer than the other
cords in every case. Also see that the cables do not come in contact with the pump (
4
)
or other hot objects such as the water pipelines at any point, so that the insulation is not
damaged.
6. Connect the other end of the power cord to the power grid via the separator which is
absolutely required in all cases.
7. Secure the individual mains connections according to the cable cross section and the
maximum power consumption. Note that the separation distance between the poles must
be a minimum of 3.0 mm.
Installation example: Compact devices WH-MDC09H3E5 and WH-MHF12G9E8
5
8
12
11
4
D
1
3
2
C
A
2
1
3
4
5
6
7
8
9
10
B
A WH-MDC09H3E5: Detailed view of the Rear Side
1 Rear side of the Cabinet
2 Cable gland for power cord 1
3 Cable gland for power cord 2
B WH-MDC09H3E5: Detailed view of the Front
Side
4 Pump
5 Cable binder
6 Internal cable gland for power cord 1
7 Internal cable gland for power cord 2
8 Cable holders / Main lead cleats
9 FI switch for mains connection 1
10 FI switch for network connection 2
C WH-MHF12G9E8: Detailed view of the Rear Side
1 Rear side of the Cabinet
2 Cable gland for power cord 1
3 Cable gland for power cord 2
D WH-MHF12G9E8: View of the Front Side
4 Pump
5 Cable binder
8 Cable holders / Main lead cleats
11 FI switch for network connection 2
12 FI switch for mains connection 1
Installation example: Outdoor unit WH-UD12HE8
2
3
4
5
1
A
6
7
8
9
10
B
Terminals on
outdoor unit
Terminals on
indoor unit
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN11
N
L
N
L
22
POWER SUPPLY 2
LB1
LB2
LB3
N
POWER SUPPLY 1
LA1
LA2
LA3
N
45
A
Connection of the connecting cable
between indoor and outdoor unit
C
A Connection of the connecting cable
1 Rubber cable sleeve (available or not, depending
on model)
2 Cable gland (one of three options depending on the
model)
3 Cable binder
4 Cable holder
5 Terminal blocks
B Insulation of the pipe and cable
6 Cable tape or cable duct
7 Fastening clips
8 Coolant fluid line
9 Coolant - hot gas line
10 Connecting cable between indoor and outdoor unit
C Detailed view of terminal block on outdoor unit
6.8.1.3
Connecting power cord to the compact device
The following method is applicable as appropriate for all compact devices, but will be explained
here on the basis of the example of a B8 model compact device (H-Generation) and B9 model
(G-Generation) (
→
Installation example: Compact devices, p. 179
).
Carry out the following steps to connect the power cord to the compact device:
1. Open the compact device (
→
6.5 Opening devices, p. 148
).
2. If a cover is available on the rear side of the cabinet on the cable gland (depends on mod-
el), remove the cover before connecting the cable and re-assemble it afterwards.
If a cable sleeve is available (depends on model), cut the cable sleeve in the form of a
cross using a knife.
3. Guide the cable through the cable glands (
2
,
3
) into the device.
4. Fix the cables using cable binders (
5
) and cable holders (cable reliefs) (
8
).
Summary of Contents for Aquarea B1
Page 2: ...Notes ...
Page 116: ...Notes Notes ...