168
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Installation
169
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Installation
Carry out the following steps to connect the outflow hose to the condensation outflow of the
outdoor unit:
1.
Assemble the supplied outlet bend with seal on the condensation outflow on the under
-
side of the outdoor unit, as shown in the figures below.
2.
Seal the openings on the underside of the outdoor unit (model-dependent number: 7 or 8)
using the supplied rubber sealing caps.
3. Push the hose over the outlet bend.
4.
Ensure that the outflow hose is seated firmly. Use a hose clip to attach the hose, if neces
-
sary (to be provided on site).
5.
Lay the outflow hose in a constant downward alignment. For large outflow hose lengths,
you may want to use a metal support (provided on site) to prevent the hose from bending.
1
2
3
4
Detail view from below
1 Condensation outlet
2 Outlet bend
3 Openings
(7 or 8, depending on model)
4 Rubber seal caps
Compact devices
Carry out the following steps to connect the outflow hose to the condensation outflow of the
compact device:
1.
Slide the outflow hose onto the condensation outlet socket on the compact device.
2.
Ensure that the outflow hose is seated firmly. Use a hose clip to attach the hose, if neces
-
sary (to be provided on site).
3.
Lay the outflow hose in a constant downward alignment. For large outflow hose lengths,
you may want to use a metal support (provided on site) to prevent the hose from bending.
1
View from below
1 Condensation outlet
6.7.2.1
Connecting the condensation outflow hose
Indoor units
Carry out the following steps to connect the outflow hose to the condensation outflow of the
indoor unit:
1.
Assemble the supplied outlet bend with seal on the condensation outflow on the under
-
side of the indoor unit, as shown in the illustrations below.
2. Push the hose over the outlet bend.
3.
Ensure that the outflow hose is seated firmly. Use a hose clip to attach the hose, if neces
-
sary (to be provided on site).
4.
Lay the outflow hose in a constant downward alignment into a suitable collection fixture
for the condensation (to be provided on site).
Combination Hydro-module H-Generation
Hydro-module H-Generation
Detail view from below
1
2
3
2
3
Detail view from below
1
1 Condensation outlet
2 Sealing washer
3 Outlet bend
Outdoor units
!
IMPORTANT
Also use the following instructions at the time of installation of the condensation outflow hose on
the outdoor unit:
●
When using the outlet bend, the outdoor unit should be mounted on a sub-base at
least 50 mm in height.
●
For installation of the outdoor unit on a foundation, the installation method with a
strip foundation and gravel filling is recommended (
→
5.2.2.3 Securing the outdoor
unit, p. 92
). For a safe drainage of condensation water, even at outside tempera
-
tures below 0 °C, a drain pipe is recommended, reaching into the frost-free area of
the underground.