MECH-21
Waving Measurement Procedures
1. Press “SPACE” key to perform the Peak Hold in 30 seconds while linearity is displayed.
2. After sampling the Peak Hold, press “SHIFT” and “ } ” key simultaneously on the Key Board, then the
numerical values of “Linearity” and “Waving” are displayed. Confirm that the numerical values are in the
specification. Also confirm that the waving level is almost equal from the entrance to the exit side. If the
“Linearity” or “Waving” is out of specification, adjust height of S2 or T2 post.
3. Press the ESC key to return to the main menu.
Confirm this value
Linearity: 2.0um
Waving : 2.2um
Sensitivity: 103.2mV /um
(92.4mV/um 114.0mV/2.2um)
When a waving value is more than 1.5um.
Max Line
Min Line
Confirm this value
When a waving value is less than 1.5um.
Summary of Contents for AJ-YA120AG
Page 3: ... 3 ...
Page 4: ... 4 AJ HD1200AE ...
Page 5: ... 5 ...
Page 6: ... 6 AJ YA120AG AJ YAD120AG ...
Page 8: ... 8 AJ HD1200AP ...
Page 9: ... 9 ...
Page 10: ... 10 AJ HD1200AE ...
Page 11: ... 11 ...
Page 12: ... 12 AJ YA120AG AJ YAD120AG ...
Page 13: ...FCD0405NTKK67E494E495 ...
Page 312: ...73 73 73 73 31 95 89 MECHANICAL CHASSIS ASSEMBLY 1 MPL 1 ...
Page 314: ...MECHANICAL CHASSIS ASSEMBLY 2 MPL 3 ...
Page 316: ...58 59 57 36 59 59 E9 SUB CHASSIS ASSEMBLY MPL 5 37 55 38 39 55 55 57 55 55 ...
Page 318: ...FRONT LOADING ASSEMBLY MPL 7 E22 112 109 104 109 104 ...
Page 493: ...E1 2 1 2 3 10 4 5 6 9 1 E2 8 7 PACKING ASSEMBLY AJ YA120AG OPL 3 ...
Page 552: ...MECHANICAL CHASSIS ASSEMBLY 2 MPL 3 ...
Page 554: ...58 59 57 36 59 59 E9 SUB CHASSIS ASSEMBLY MPL 5 37 55 38 39 55 55 57 55 55 ...
Page 556: ...FRONT LOADING ASSEMBLY MPL 7 E22 112 109 104 109 104 ...
Page 634: ...E1 2 1 2 3 10 4 5 6 9 1 E2 8 7 PACKING ASSEMBLY AJ YA120AG OPL 3 ...