17-26
17.5.2 Each Axis Information & Monitor Area
These are the areas for the information of each axis and monitoring operation states.
Axis information of axis 1
Bank
Offset
address
Name
Descriptions
Defaul
t value
Setting
range
Unit
01H
031H
External terminal
input monitor of
axis 1
Stores the information of I/O connected to each axis.
034H
Moving amount
automatic check
value of axis 1
Stores the maximum value of difference
between the command value and
feedback value of the unit.
-
-
-
035H
036H
Pulse input
value of axis 1
Stores the pulse input values (pulser,
feedback pulse, couner) according to the
pulse input purposes.
The pulse input value is stored by
integrating the pulse input values until
changing the pulse input purpose or
clearing the pulse input.
-
-
pulse
037H
038H
Acitve table or
execution done
table of axis 1
Stores the number of active positioning
table or when the operation completed.
1
1 to
600
-
039H
Auxiliary output
code of axis 1
Stores the auxiliary output code.
0
-
03AH
Repeat count
setting value of
axis 1
Stores the setting value of repeat count
for positioning.
1 is stored not to repeat the operation.
When specifying the repeat count to be
unlimited, 255 is stored.
0
0 to
255
times
03BH
Repeat count
current value of
axis 1
Stores the repeat count in operation.
1 is stored not to repeat the operation.
When the repeat count exceeds the
upper limit, it returns to 0.
0
0 to
65,535
times
03CH
Current value of
axis 1
Stores the current value.
0
-
pulse
03DH
03EH
Unit system
conversion
current value of
axis 1
Stores the current value after the unit
was converted.
0
-
-
03FH
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......