15-10
Error
code
Error name
Description
Object
Clear
Countermeasures
4301H
Absolute/Incremental
setting error
A value other than the
absolute/increment is set for the
move method.
Each axis
A
4302H
Dwell time error
The setting value of the dwell time
is out of the range.
Each axis
A
4303H
Positioning starting
table No. error
The specified table number is 0,
or it exceeds the maximum table
number.
Each axis
A
4304H
Table setting error
The last table of the positioning
setting tables is not point E.
Each axis
A
4400H
Positioning movement
amount setting error
The movement amount of the
positioning operation is out of the
range.
Each axis
A
4401H
Positioning rotating
acceleration/decelera-
tion type error
The acceleration/deceleration
type of the positioning operation is
incorrect.
Each axis
A
4402H
Positioning
acceleration time error
The acceleration time of the
positioning operation is out of the
range.
Each axis
A
4403H
Positioning
deceleration time error
The deceleration time of the
positioning operation is out of the
range.
Each axis
A
4404H
Positioning target
speed error
The target speed of the
positioning operation is out of the
range.
Each axis
A
4500H
Interpolation type error
The setting of the interpolation
type is incorrect.
Each axis
A
4504H
Circular interpolation
not executable
The parameter of the circular
interpolation (such as center point
or pass point) is incorrect.
Each axis
A
4505H
Spiral interpolation not
executable
The error occurred during the
spiral interpolation as the setting
value is incorrect.
Each axis
A
4600H
Pulse input setting
error
The setting of the pulse input
mode is incorrect.
Each axis
A
Cehck the setting value.
Check the combination of
the input mode, input
multiplying, input purpose.
4605H
Pulse count changed
value setting error
The specified pulse count
changed value is out of the range.
Each axis
A
Check the setting value.
4609H
Moving amount
automatic check
operation method
setting error
The setting for the operation of
moving amount automatic check
function is incorrect.
Each axis
A
4610H
Moving amount
automatic check
correction numerator
setting error
The moving amount automatic
check correction numerator is out
of the range.
Each axis
A
4611H
Moving amount
automatic check
correction denominator
setting error
The moving amount automatic
check correction denominator is
out of the range.
Each axis
A
4613H
Moving amount
automatic check
interval setting error
The moving amount automatic
check interval is out of the range.
Each axis
A
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......