x
Increment method (relative value control method)
This is a control method in which the distance from the current position to the target position is specified
as a relative position. This is specified on the positioning data editing screen of the Configurator PM.
Line driver output
This is one output format used in pulse output signal circuits, in which the push - pull output of the line
driver is used. Because this format offers better resistance to noise than the open collector output format,
a larger distance to the driver is possible. The line driver must be supported on the motor driver side.
Most servo motor drivers are equipped with this format.
Open collector output
This is one output format used in pulse output signal circuits, enabling to make connections in
accordance with the voltage of the power supply being used by connecting an external resistance. This
is used when connecting a driver that does not have line driver input, such as a stepping motor.
Automatic operation
This is an operation to be automatically executed, and means a position control.
Manual operation
This is an operation to be executed for an initial boot or adjustments. The home return, JOG operation
and pulser operation are manual operations.
Position control
This is a generic term for the E point contro, P point control and C point control. For each control, the
control of a single axis and the interpolation control of multiple axes are available.The interpolation
control can be selected from a 2-axis linear interpolation, 2-axis circular interpolation, 3-axis linear
interpolation and 3-axis sprial interpolation.
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......