8-29
8.3.5 Operation of Master and Slave Axes
Operation of master and slave axes
Various positioning parameters should be set to perform operations on the positioning unit. The
parameters to be applied vary in the synchronous operation as follows.
Parameter name
Operation during synchronous operation
Unit setting
Operates by the setting of each axis.
Specify the same settings for the axes to be
synchronized when performing the synchronous
operation.
Pulse number per rotation
Moving amount per rotation
Pulse I/O setting
Limit switch
Follows the operation of the master axis during the
synchronous operation.
Limit switch connection
Software limit (Positioning control)
Software limit (Home return)
Software limit (JOG operation)
Upper limit of software limit
Lower limit of software limit
Auxiliary output mode
Auxiliary output ON time (ms)
Auxiliary output Delay rate
Home return
– Setting code
Varies depending on the operation mode of the
synchronous operation.
Synchronous mode A: Operates by the setting of
each axis.
Synchronous mode B: Follows the operation of a
master axis.
Home return
– Direction
Home return
– Acceleration time
Home return
– Deceleration time
Home return
– Traget speed
Home return
– Creep speed
JOG operation
– Acceleration/Deceleration type
Follows the operation of the master axis during the
synchronous operation.
JOG operation
– Acceleration time
JOG operation
– Deceleration time
JOG operation
– Target speed
JOG positioning operation setting code
JOG positioning operation acceleration time
JOG positioning operation deceleration time
JOG positioning operation target speed
Emergency stop deceleration time (ms)
The operation varies according to the type of stop
operations.
For the details, see the following
“Stop function in
synchronous operation
”.
Limit stop deceleration time (ms)
Error stop deceleration time (ms)
Pulser operation setting code
Operates by the setting of each axis.
Specify the same settings for the axes to be
synchronized when performing the synchronous
operation.
Pulser operation ratio numerator
Pulser operation ratio denominator
Stop function in synchronous operation
If the stop operaiton is executed for the master and slave axes during the synchronous operation, the
operation is as follows.
Axis requested to stop
Stop operation
Operational overview
Master axis
Slave axis
System stop
All axes stop without
deceleration time.
All axes stop.
Emergency stop
Deceleration stop
A specified axis stops with
a deceleration time.
Stops with the deceleraiton time for the master axis.
Limit stop
Stops with a deceleration
time when a limit occurred. Stops with the deceleraiton time for the master axis.
After stop, the error code occurred on the master
axis is set for the master/slave axes.
Error stop
Stop the operation with a
deceleration time when an
error occurs.
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......