7-16
Parameter name
Description
Software limit (Positioning control)
Enable/disable the software limit in the positioning control.
Software limit (Home return)
Enable/disable the software limit in the home return.
Software limit (JOG operation)
Enable/disable the software limit in the JOG operation.
Upper limit of software limit
The upper limit value of the software limit.
Lower limit of software limit
The lower limit value of the software limit.
Auxiliary output mode
Enable/disable the auxiliary output contact and auxiliary output
code.
Auxiliary output ON time (ms)
The time that the auxiliary output contact is ON.
Moving amount check
The operation after checking the moving amount when using
the moving amount check function.
Moving amount check value (Pulse) The checking threshold for the moving amount check function.
Moving amount check correction
numerator
Execute the moving amount check function by multiplying the
pulse input value by the following ratio.
(Moving amount check correction numerator) / (Moving amount
check correction denominator)
Moving amount check correction
denominator
Moving amount check time (ms)
The time interval for executing the moving amount check
function.
Startup speed
The startup speed for all operations (Initial speed)
Home return
– Setting code
The pattern of the home return.
Home return
– Direction
The operating direction of the home return.
Home return
– Acceleration time
The acceleration time in the home return.
Home return
– Deceleration time
The deceleration time in the home return.
Home return
– Target speed
The target speed in the home return.
Home return
– Creep speed
The speed to search the home position after the proximity
input.
Home return
– Coordinate origin
The current value after the completion of the home return.
JOG operation
– Acceleration/
Deceleration pattern settings
The acceleration/deceleration pattern mode in the JOG
operation.
JOG operation
– Acceleration time
The acceleration time in the JOG operation.
JOG operation
– Deceleration time
The deceleration time in the JOG operation.
JOG operation
– JOG target rate
The target rate in the JOG operation.
Emergency stop deceleration time
(ms)
The deceleration time when the emergency stop is requested
by the input contact.
Limit stop deceleration time (ms)
The deceleration time for the deceleration operation when the
limit is input.
Error stop deceleration time (ms)
The deceleration time for the deceleration operation when an
error occurs
J point control
– Accel./Decel.
Pattern
The acceleration/deceleration pattern mode when performing
the J point control (speed point)
J point control
– Acceleration time
(ms)
The acceleration time when performing the J pont control
(speed point)
J point control
– Deceleration time
(ms)
The deceleration tiem when performing the J point control
(speed pont)
J point control
– Target speed
The target speed when performing the J point contro. (speed
point)
Pulser operation setting code
The pulser input (1 to 3) in the pulser operation.
Pulse input method
The input method in the pulser operation
Pulser operation ratio numerator
No. of movement pulse is calculated by multiplying the No. of
input pulse from the pulser by the ratio below.
(Numerator of ratio of pulser operation)/(Denominator of ratio of
pulser operation)
Pulser operation ratio denominator
Pulse operation maximum speed
The maximum operation speed in the pulser operation
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......