15-9
A: Available N/A: Not available
Error
code
Error name
Description
Object
Clear
Countermeasures
4031H
Synchronous operation
method setting error
The operation setting for the
synchronous operation difference
check function is incorrect.
Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
setting value, please
contact us.
4042H
Pulser setting error
The pulser input mode is
incorrect.
The pulser operation method is
incorrect.
The pulser operation maximum
speed is incorrect.
Each axis
A
4043H
Pulser disable error
The pulse input purpose for the
axis that has been set to enable
the pulser input is not set to
“Pulser”.
Each axis
A
Check the the setting of
pulser input purpose.
Set the input purpose to
“Pulser” when using the
pulser.
4044H
Speed rate error
The setting of the speed rate is
out of the range.
Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
setting value, please
contact us.
4050H
Startup speed error
The setting of the startup speed is
out of the range.
Each axis
A
4080H
JOG positioning
acceleration/decelerati
on method error
The acceleration/deceleration
method of the JOG positioning is
out of the range.
Each axis
A
4081H
JOG positioning
acceleration time error
The acceleration time of the JOG
positioning is out of the range.
Each axis
A
4082H
JOG positioning
deceleration time error
The deceleration time of the JOG
positioning is out of the range.
Each axis
A
4083H
JOG positioning target
speed error
The target speed of the JOG
positioning is out of the range.
Each axis
A
4102H
Home return target
speed error
The target speed of the home
return is out of the range.
Each axis
A
4105H
Home return
acceleration time error
The acceleration time of the home
return is out of the range.
Each axis
A
4106H
Home return
deceleration time error
The deceleration time of the home
return is out of the range.
Each axis
A
4107H
Home return setting
code error
The home return setting code is
incorrect.
Each axis
A
4110H
Home return creep
speed error
The creep speed of the home
return is out of the range.
Each axis
A
4111H
Home return returning
direction error
The moving direction of the home
return is out of the range.
Each axis
A
4112H
Home return limit error
The limit switch is disabled.
(It occurs when the home return
method is set to the stop-on-
contact method 1 or 2.)
Each axis
A
4120H
Coordinate origin error
The coordinate origin is out of the
range.
Each axis
A
4201H
JOG operation target
speed error
The target speed of the JOG
operation is out of the range.
Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
setting value, please
contact us.
4203H
JOG operation
acceleration/decelera-
tion type error
The acceleration/deceleration
type of the JOG operaiton is
incorrect.
Each axis
A
4204H
JOG operation
acceleration time error
The acceleraiton time of the JOG
operation is out of the range.
Each axis
A
4205H
JOG operation
deceleration time error
The deceleraiton time of the JOG
operation is out of the range.
Each axis
A
4250H
Current value update
error
The setting value of the current
value update is out of the range.
Each axis
A
A: Available N/A: Not available
Summary of Contents for AFP243710
Page 16: ...xiv ...
Page 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 39: ...Chapter 4 Power On Off and Items to Check ...
Page 44: ...4 6 ...
Page 45: ...Chapter 5 Preparation For Operation ...
Page 53: ...5 9 ...
Page 55: ...Chapter 6 I O Allocation ...
Page 63: ...Chapter 7 Setting Tool Configurator PM ...
Page 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 40 ...
Page 103: ...Chapter 8 Automatic Operation Position Control ...
Page 115: ...8 13 ...
Page 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Page 139: ...Chapter 9 Manual Operation JOG Operation ...
Page 144: ...9 6 ...
Page 145: ...Chapter 10 Manual Operation Home Return ...
Page 151: ...Chapter 11 Manual Operation Pulser Operation ...
Page 155: ...Chapter 12 Stop Functions ...
Page 158: ...12 4 ...
Page 159: ...Chapter 13 Supplementary Functions ...
Page 171: ...Chapter 14 Precautions During Programming ...
Page 175: ...Chapter 15 Errors and Warnings ...
Page 186: ...15 12 ...
Page 187: ...Chapter 16 Troubleshooting ...
Page 190: ...16 4 ...
Page 191: ...Chapter 17 Specifications ...
Page 241: ...Chapter 18 Dimensions ...
Page 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Page 243: ...Chapter 19 Sample Programs ...
Page 247: ...19 5 ...
Page 250: ...19 8 ...
Page 251: ...Chapter 20 Driver Wiring ...
Page 261: ......