71 – Error Code Diagnostic Chart
YES
NO
While unit is attempting to go to ignite,
check DC voltage across yellow and black
wires on Molex connector “K”:
75 – 100 DC VOLTS
Is the DC voltage
OK?
Attempt to operate again.
If the unit malfunctions due to an Error
Code 71:
Replace Control Board
Reset the water heater and attempt to operate again.
If the unit malfunctions due to an Error Code 71:
Replace Gas Control Valve