SVC 820-Tankless Gas Trouble Shooting Manual Page |
31
31
BLOWER MOTOR
Diagnostic Chart
YES
NO
NO
YES
YES
NO
Test DC voltage across black and red
wires on connector “G”:
144 – 192 DC VOLTS
Is the DC voltage
OK?
Remove and reinsert connector “G” at
Control Board.
Attempt to operate unit again.
IF unit continues to display Error Code 10:
Replace Control Board
Is the DC voltage
OK?
Press and hold down “MAX” button on Control Board
to activate the Blower Motor. While Blower Motor is
running, test DC voltage across black and white wires
on connector “G”:
12 – 18 DC VOLTS
Press and hold down “MAX” button on Control Board
to activate the blower motor. While blower is
running, test DC voltage across black and blue wires
on connector “G”:
4 – 10 DC VOLTS
Remove and reinsert connector “G” at
Control Board.
Attempt to operate unit again.
IF unit continues to display Error Code 10:
Replace Control Board
Is the DC voltage
OK?
Replace Blower Motor
Attempt to operate unit again. If unit
continues to display Warning Code 10:
Control Board and Blower Motor are ‘OK’:
CHECK VENTING & GAS SUPPLY
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...