[How To Check Test Point Gas Pressure]
When press the Maximum Button (SW2) or Minimum Button (SW1), the combustion is fi xed at Maximum or Minimum
and then the LED of remote control displays as follows.
1
__
L
__
Minimum Combustion
1st Step Combustion
4
__
H
__
Maximum Combustion
4th Step Combustion
Note: Make sure that you adjusted the DIP switch setting, if necessary, for the high altitude setting, etc.
Standard Pressure (inch in w.c.)
PHH-32RDV
PHH-25RDV
L.P.
NAT
L.P.
NAT
Minimum Capacity
0.91/11.0
0.71/7.1
0.91/11.0
0.71/7.1
Maximum Capacity
3.64/11.0
3.13/7.1
2.24/11.0
1.97/7.1
Slow Ignition Point
2.76/11.0
2.52/7.1
2.76/11.0
2.52/7.1
PHH-32ROF
PHH-25ROF
L.P.
NAT
L.P.
NAT
Minimum Capacity
0.89/11.0
0.65/7.1
0.89/11.0 0.65/7.1
Maximum Capacity
3.46/11.0
3.11/7.1
2.17/11.0 1.97/7.1
Slow Ignition Point
2.76/11.0
2.68/7.1
2.76/11.0 2.68/7.1
- 128 -
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...