SVC 820-Tankless Gas Trouble Shooting Manual Page |
63
63
32 – Error Code Diagnostic Chart
Check the resistance across 2 white wires
on bottom Molex:
7k – 23K Ohms
Replace wiring harness for Connector “R”
on Control Board
Clean Scale Build-Up on Heat Exchanger
Thermistor. Retest Thermistor.
IF test OK, the water heater appears to be
normal. Attempt to operate unit again.
IF resistance NOT OK:
Replace Heat Exchanger Thermistor
NO
YES
YES
NO
Is the resistance
to the Heat
Exchanger
Thermistor OK?
Is the continuity
across all wires
OK?
Remove Molex from connector “R” at Control Board.
Check continuity from black #3 wire at Molex
connector “R” and black wire at Yellow* Molex
located behind Control Board. Check continuity from
Yellow* #5 wire at Molex connector “R” and Yellow*
wire at Yellow* Molex located behind Control Board
Attempt to operate unit again.
If the unit malfunctions due to an Error Code 32:
Replace Control Board
*High Efficiency (Condensing) Units ONLY:
Green wire & Green Molex
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...