82 |
Page SVC 820 Tankless Gas Trouble Shooting Manual
82
72 – Error Code
Explanation:
Flame Rod(s) malfunction. Flame Rod(s) is
detecting the presence of flame BEFORE igniter is
activated.
Diagnostic Checks:
•
Flame Rod(s)
•
Gas Control Valve
FLAME ROD(s) & GAS CONTROL VALVE DIAGNOSTICS:
Remove and reinsert terminals on Flame Rod(s)*.
Attempt to operate unit again. IF 72 Error Code does
NOT display, unit had a loose connection.
Turn power OFF. Remove and reinsert white
connector “M” and blue connector “T” on Control
Board.
1
2
Flame Rod(s)*
*Indoor Units ONLY:
2 Flame Rods
Visually inspect Gas Control Valve
wiring harnesses for loose
connections or damaged wiring.
Gas Control Valve is located on
lower right side of unit.
Locate Sight Glass.
Sight Glass
Gas Control Valve
3