SVC 820-Tankless Gas Trouble Shooting Manual Page |
85
85
76 – Error Code Diagnostic Chart
NO
YES
YES
NO
Unplug unit and remove Remote
Thermostat wires from wiring terminals
on bottom of unit. Plug unit in and open
a hot water source.
Did the unit go to
main burner?
Attempt to operate unit again. If the unit
malfunctions due to an Error Code 76:
Replace Remote Control
Did the unit go to
main burner?
Unplug unit. Use a short piece of new thermostat
wire to connect the Remote Control directly to
Remote Control wiring terminals at bottom of unit.
Plug unit in and open a hot water source.
The wiring is defective. Replace Remote Control
wiring.
Replace Remote Control