SVC 820-Tankless Gas Trouble Shooting Manual Page |
57
57
24 – Error Code Diagnostic Chart
YES
NO
Unplug unit and remove Remote Control
wires from wiring terminals on bottom of
unit. Use a new short piece of wire to
connect the Remote Control directly to
the Remote Control Wiring Terminals
located at bottom of unit. Plug unit in
and open a hot water source.
Did the unit
display Error
Code 24?
The wiring is defective.
Replace Remote Control wiring.
Replace Remote Control