- 132 -
Instruction for changing the setting to 140ºF (60ºC
)
or
185ºF (85ºC)
:
WARNING: Improper adjustment, alternation, service or maintenance can cause property
damage, personal injury, or death.
Maximum Temperature Adjustment by the Main Remote Control (UMC-117)
Required adjustment for up to 140ºF (60ºC) water temperature setting for Residential product or 185ºF (85ºC)
water temperature setting for Commercial version.
Follow the instruction below if it is determined that a setting of up to 140º (60ºC) or 185ºF (85ºC) is required.
(1) Turn on the remote control (UMC-117). Turn off the gas and water shutoff valves.
(2) Press the UP arrow temperature adjustment button on the remote control for several times and set the temperature
at 120ºF (49ºC).
(3) Press and hold the UP button on remote control for more than 5 seconds. Number (120) on the display of the re-
mote control will begin to blink.
(4) While the number is blinking, push the UP arrow temperature adjustment button and the DOWN arrow temperature
adjustment button at the same time. The display of the remote control will show “140”.
(5) Push the UP or DOWN button to set desired temperature.
(6) Turn on the gas and water shutoff valves.
(7) Check and ensure safe operation and performance of the water heater.
Note: Commercial version requires the adjustment by the commercial conversion kit.
WARNING: Changing this setting is done at your risk.
WARNING: Water Temperature over 125ºF (52ºC) can cause severe burns instantly or death from scalds.
Children, disabled and elderly persons are at highest risk of being scalded. See the Instruction Manual before
setting the temperature on the remote control. FEEL WATER BEFORE BATHING or SHOWERING. DO NOT
leave a child in the bath unsupervised.
Danger: Hotter water increases the potential for Hot Water SCALDS.
Notice: For safety reasons the BATH Remote Control(s) cannot be adjusted to temperature above 120ºF (49ºC).
Note: We recommend that you install the thermostatically controlled tub and shower valve & tempering valve
for your safety.
DO NOT execute the following adjustment if the setting of up to 140ºF (60ºC) or 185ºF (85ºC) is not required.
°F
PRIORITY
POWER
ON/OFF
Higher (Hotter)
Lower (Cooler)
In Use Indicator
(Lit during operation)
LED Display
(Display water
temperature and
error code)
Priority
Indicator
Temperature
Adjustment
Buttons
ON/OFF
Indicator
100 102 104 106 108 110 112 114 116 118 120*
38 39 40 41 42 43 44 46 47 48 49*
85
29
125 130 135 140 150 160 170 185
°F
52 54 57 60 66 71 77 85
°C
Temperature Time to Produce Serious Burn Temperature Time to Produce Serious Burn
120°F (49°C) More than 5 minutes 140°F (60°C) Less than 5 seconds
125°F (52°C) 1-1/2 to 2 minutes 145°F (63°C) Less than 3 seconds
130°F (54°C) About 30 seconds 150°F (66°C) About 1-1/2 seconds
135°F (57°C) About 10 seconds 155°F (68°C) About 1 second
Table courtesy of The Shriners Burn Institute
Time/Temperature Relationship in Scalds
Summary of Contents for PH2-20R DVSN
Page 158: ... 158 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 159: ... 159 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 160: ... 160 Schematic Disassembly PH2 20RDVS PH2 25RDVS PH2 28RDVS ...
Page 162: ... 162 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 163: ... 163 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 164: ... 164 Schematic Disassembly PH2 20ROF PH2 25ROF PH2 28ROF ...
Page 166: ...Schematic Disassembly PHH 32RDV PHH 25RDV 166 ...
Page 167: ...Schematic Disassembly PHH 32RDV PHH 25RDV 167 ...
Page 169: ... 169 Schematic Disassembly PHH 32ROF PHH 25ROF ...